📅 Maintenance Planning for Facilities Teams — UK FM Guide
A UK guide to maintenance planning for facilities teams — planned, statutory and reactive maintenance, building a PPM schedule, statutory compliance, hard vs soft FM, contractors, and CAFM systems.
For facilities teams, maintenance is rarely about a single machine — it’s about keeping an entire building or estate running: the heating and cooling, the lifts, the fire systems, the water, the electrics, the fabric, and everything in between, across one site or many. Doing that well takes planning. Without it, facilities maintenance becomes a reactive scramble from one breakdown to the next, statutory deadlines get missed, budgets spiral, and the building deteriorates. With good planning — a structured PPM schedule, statutory compliance tracked, work organised and resourced, and the right systems — facilities maintenance becomes proactive, compliant, cost-effective, and far less stressful.
Maintenance planning for facilities teams is the discipline of organising and scheduling all the maintenance a building or estate needs — planned preventive maintenance, statutory compliance, and reactive repairs — so it gets done efficiently, on time, and within budget. It brings together the planned schedule of recurring tasks, the legally-required inspections and servicing, the management of reactive work, the resourcing (in-house teams and contractors), and the systems (increasingly CAFM software) that hold it all together. For facilities managers, getting this planning right is the difference between a well-run, compliant building and a chaotic, risky one.
This guide covers maintenance planning for facilities teams — why planning matters in FM, the types of FM maintenance (planned, statutory, reactive), building a PPM schedule, statutory compliance (the big one for FM), hard vs soft FM, resourcing and contractors, CAFM systems, planning and prioritising work, budgeting, KPIs, and the common mistakes. It complements our Preventive Maintenance, Reducing Equipment Downtime, and Facilities Cleaning & Hygiene guides.
Why Planning Matters in Facilities Management
- Compliance: Buildings have extensive statutory maintenance obligations (fire, lifts, electrical, water/Legionella, gas, etc.) — planning ensures these legal duties are met on time. This is arguably the single most important reason.
- Avoiding reactive chaos: Without planning, FM becomes firefighting — lurching from breakdown to breakdown, expensively and stressfully (see our Preventive Maintenance guide).
- Building availability and comfort: Keeping the building functioning — comfortable, safe, and operational for occupants.
- Cost control: Planned maintenance is cheaper than reactive; planning controls and forecasts costs.
- Asset life: Looking after building services and fabric extends their life and defers major capital spend.
- Safety: Much FM maintenance is safety-critical (fire systems, lifts, electrical) — planning keeps occupants safe.
- Across multiple sites: For estates, planning coordinates maintenance across many buildings.
Types of FM Maintenance
Planned Preventive Maintenance (PPM)
Scheduled, recurring maintenance of building services and assets — servicing HVAC, checking and testing systems, routine upkeep — done proactively at set intervals to prevent failures and keep systems running (see our Preventive Maintenance guide). The backbone of planned FM.
Statutory / Compliance Maintenance
Legally-required inspections, testing, and servicing of regulated building systems — fire safety, lifts (LOLER), electrical (EICR/PAT), water systems (Legionella), gas, pressure systems, emergency lighting, and more. Mandatory, at defined frequencies, by competent persons, with records. The compliance layer that FM absolutely must get right (see our Asset Inspection guide).
Reactive / Corrective Maintenance
Responding to faults, breakdowns, and requests as they arise — repairs, fixing reported issues. Inevitable to some degree, but minimised by good PPM. Managed through a helpdesk/reporting and work-order system, prioritised by urgency (see our Reducing Equipment Downtime guide).
Building a PPM Schedule
The PPM schedule is the planned calendar of recurring maintenance:
- Asset register first: Start with a register of all the assets/systems to be maintained — you can’t plan maintenance for assets you haven’t listed (see our Industrial Maintenance Checklist guide).
- Define tasks and frequencies: For each asset, the maintenance tasks and their frequencies — from manufacturer recommendations, statutory requirements, standards (e.g. SFG20, the recognised FM maintenance standard), and experience.
- Schedule across the year: Lay tasks out across an annual calendar — balancing the workload and ensuring nothing is missed.
- Include statutory tasks: Build all statutory inspections/servicing into the schedule with their legal frequencies — these are non-negotiable.
- Assign responsibility: Who does each task — in-house team or contractor.
- Use a system: Manage the schedule in CAFM software (below) rather than spreadsheets where possible.
- Review: Keep the schedule updated as assets change.
Statutory Compliance — the FM Priority
Statutory compliance is the area FM teams must get right above all, because it’s a legal duty and safety-critical. Key areas include:
- Fire safety: Fire alarm testing/servicing, emergency lighting, extinguishers, fire doors, sprinklers — under fire safety law (see our Fire Safety Equipment and Emergency Lighting guides).
- Lifts: LOLER thorough examination (typically 6-monthly for passenger lifts) plus servicing (see our Asset Inspection guide).
- Electrical: Fixed wire testing (EICR) and PAT (see our Electrical Maintenance Safety guide).
- Water / Legionella: Legionella risk assessment and water system management/monitoring (a significant duty under COSHH/HSE guidance).
- Gas: Gas safety checks and servicing by registered engineers.
- HVAC / air conditioning: F-Gas, TM44 air-con inspections, ventilation (LEV where applicable).
- Pressure systems, asbestos management, and others as applicable.
- Track rigorously: A compliance calendar/tracker ensuring every statutory task is scheduled, done on time, and certificated — with the records to prove it.
Hard FM vs Soft FM
- Hard FM: The physical building and its systems — building fabric, HVAC, electrical, plumbing, lifts, fire systems. The maintenance and compliance covered by this guide. Largely non-discretionary (especially statutory).
- Soft FM: Services that make the building pleasant and functional to occupy — cleaning, security, catering, grounds, waste, pest control (see our Facilities Cleaning & Hygiene guide).
- Both planned: Both hard and soft FM benefit from planning and scheduling — though hard FM carries the statutory weight.
Resourcing: In-House and Contractors
- In-house team: Directly-employed FM/maintenance staff for day-to-day maintenance, minor repairs, and responsiveness.
- Specialist contractors: Specialist and statutory work (lifts, fire systems, air-con, etc.) by qualified contractors — the competent persons for statutory examinations.
- The mix: Deciding what to do in-house vs outsource — by capability, cost, and the specialist/statutory nature of the work.
- Managing contractors: Selecting competent contractors, managing them, permits to work, checking their work and certificates, and contractor safety on site.
- Coordinating: Scheduling and coordinating contractor visits within the PPM plan.
- Resource planning: Ensuring enough resource (people, skills, contractors) to deliver the plan.
CAFM Systems
Computer-Aided Facilities Management software is increasingly central to FM maintenance planning:
- What it does: Holds the asset register, schedules and issues PPM tasks, manages reactive work orders and the helpdesk, tracks statutory compliance, records work history, manages contractors, and reports.
- PPM automation: Automatically generating scheduled PPM and statutory tasks when due — so nothing is forgotten.
- Compliance tracking: Tracking statutory tasks and certificates — a major benefit for FM compliance.
- Work orders: Logging, assigning, tracking, and closing both planned and reactive jobs.
- Records and reporting: A complete maintenance history and KPI reporting.
- Better than spreadsheets: For all but the smallest operations, CAFM beats spreadsheets for managing the complexity — though the principles matter more than the tool (see our Reducing Equipment Downtime guide on CMMS/CAFM).
Planning and Prioritising Work
- Plan the work: PPM and statutory tasks scheduled in advance; reactive work logged and triaged.
- Prioritise: By safety, statutory deadlines, impact on the building/occupants, and urgency — statutory and safety-critical first.
- Balance planned and reactive: Protecting time for planned/statutory work so it isn’t crowded out by reactive demands — a constant FM challenge.
- SLAs: Response and completion targets for reactive jobs by priority.
- Coordinate access: Working around building occupants and operations — scheduling disruptive work appropriately.
- Look ahead: Forward planning for upcoming statutory dates, seasonal work (heating before winter), and lifecycle replacements.
Budgeting and Lifecycle
- Maintenance budget: Planning and forecasting the maintenance budget — PPM, statutory, reactive, and contracts.
- Planned is predictable: A good PPM plan makes costs more predictable and controllable than reactive firefighting.
- Lifecycle / capital planning: Planning for the eventual replacement of major plant (boilers, chillers, lifts) — lifecycle costing and capital budgeting, not just running repairs.
- Demonstrating value: Showing the value of planned maintenance (compliance, fewer failures, asset life) to justify the budget.
Measuring Performance
- PPM completion: The percentage of planned tasks completed on time — a core FM KPI.
- Statutory compliance: 100% statutory compliance — the non-negotiable target.
- Reactive response: SLA performance on reactive jobs.
- Planned vs reactive ratio: A higher proportion of planned work indicates a more proactive, mature operation (see our Reducing Equipment Downtime guide).
- Backlog: Tracking outstanding work.
- Cost: Maintenance cost against budget.
Common Mistakes
No PPM Schedule
Running FM reactively with no planned schedule — firefighting, missed compliance, deterioration. Build and follow a PPM schedule.
Missing Statutory Compliance
Failing to track and complete statutory tasks on time — unlawful and dangerous, the most serious FM failure. Track statutory compliance rigorously with a compliance calendar.
No Asset Register
Not knowing what assets you have to maintain. Build and maintain an asset register as the foundation of planning.
Reactive Crowding Out Planned
Letting reactive demands consume all resource so planned/statutory work slips. Protect time for planned and statutory work.
Managing Complexity on Spreadsheets
Trying to manage a complex estate’s maintenance on spreadsheets — error-prone, things missed. Use CAFM software for all but the smallest operations.
Poor Contractor Management
Not selecting competent contractors, managing them, or checking their certificates. Manage contractors properly — competence, permits, and certification.
Not Keeping Records / Certificates
No records or compliance certificates — can’t prove compliance. Keep complete records and all statutory certificates.
Underfunding Planned Maintenance
Cutting planned maintenance to save money — leading to more failures, compliance risk, and higher costs. Fund planned maintenance; it’s cheaper than the alternative.
Ignoring Lifecycle Planning
No plan for major plant replacement — then a boiler or lift fails with no budget. Plan lifecycle replacement and capital budgets.
No SFG20 or Standard
Guessing maintenance tasks and frequencies. Use a recognised standard like SFG20 plus manufacturer and statutory requirements.
Conclusion
For facilities teams, maintenance planning is what turns the enormous job of keeping a building or estate running — the HVAC, lifts, fire systems, water, electrics, and fabric — from a reactive scramble into a proactive, compliant, cost-effective operation. The core of it is bringing together three types of work: planned preventive maintenance (the scheduled servicing and checks that keep systems running), statutory compliance maintenance (the legally-required fire, lift, electrical, water/Legionella, gas, and other inspections that FM must get right above all else), and reactive repairs (minimised by good PPM and managed through a prioritised work-order system). Built on an asset register, laid out in a PPM schedule (ideally to a recognised standard like SFG20), and tracked through CAFM software, this planning ensures nothing is missed — especially the non-negotiable statutory deadlines.
Around this sit the other essentials of FM maintenance planning: resourcing the work through the right mix of in-house teams and competent specialist contractors (properly managed and certificated); prioritising work by safety and statutory deadlines while protecting planned work from being crowded out by reactive demands; budgeting for both routine maintenance and lifecycle replacement of major plant; and measuring performance through KPIs like PPM completion, statutory compliance (the 100% target), and the planned-versus-reactive ratio. Above all, statutory compliance is the FM priority — tracked rigorously, done on time, and certificated — because it’s both a legal duty and safety-critical for the building’s occupants. Plan the work, track compliance relentlessly, resource it properly, protect planned maintenance, and use the right systems, and facilities maintenance becomes the well-run, compliant, cost-effective operation a good building deserves. See our Preventive Maintenance, Reducing Equipment Downtime, and Facilities Cleaning & Hygiene guides for the related disciplines.
Frequently Asked Questions
What’s the difference between planned, statutory, and reactive maintenance in FM?
These are the three types of maintenance a facilities team manages, and they serve different purposes. Planned preventive maintenance (PPM) is scheduled, recurring maintenance of building services and assets — servicing the HVAC, checking and testing systems, and routine upkeep — carried out proactively at set intervals to prevent failures and keep systems running reliably; it’s the backbone of planned FM and is done because it’s good practice and keeps the building functioning. Statutory or compliance maintenance is the subset of maintenance that’s legally required — the inspections, testing, and servicing of regulated building systems mandated by law, such as fire safety systems, lifts (under LOLER), electrical installations (EICR and PAT), water systems (Legionella management), gas, pressure systems, and emergency lighting; these must be done at defined frequencies by competent persons, with records kept, and they’re non-negotiable because they’re both legal duties and safety-critical. Reactive or corrective maintenance is responding to faults, breakdowns, and requests as they arise — the repairs and fixes for things that have gone wrong or been reported; some reactive work is inevitable, but good PPM minimises it, and it’s managed through a helpdesk or reporting system with jobs prioritised by urgency. The key distinctions are that planned maintenance is proactive and scheduled, statutory maintenance is the legally-mandated layer that absolutely must be completed on time, and reactive maintenance is the unplanned response to failures. A well-run FM operation has a strong planned and statutory programme (which keeps the building compliant and reduces failures) and a well-managed but minimised reactive workload. The danger is an operation that’s mostly reactive, lurching from breakdown to breakdown while statutory compliance slips — which is both expensive and legally risky. Good maintenance planning brings all three types together into a coherent, managed programme.
What statutory compliance does a facilities team need to manage?
Facilities teams have extensive statutory maintenance obligations, and managing them is arguably the single most important part of FM — because they’re legal duties and safety-critical. The key areas include: fire safety — fire alarm testing and servicing, emergency lighting testing, fire extinguisher servicing, fire door inspection, and sprinkler maintenance, under fire safety legislation; lifts — thorough examination under LOLER (typically every six months for passenger lifts) plus regular servicing; electrical — fixed wire testing (the EICR, periodic inspection of the fixed installation) and portable appliance testing (PAT); water systems — Legionella risk assessment and ongoing water system management and monitoring, a significant duty given the serious health risk Legionella poses; gas — gas safety checks and servicing by registered Gas Safe engineers; HVAC and air conditioning — F-Gas requirements for refrigerant systems, TM44 air conditioning inspections, and ventilation system maintenance; and others as applicable such as pressure systems (PSSR), asbestos management (where asbestos is present), and local exhaust ventilation. The exact obligations depend on the building and its systems, but most commercial buildings carry a substantial set of these duties. The critical thing for FM teams is to identify all the statutory obligations that apply to their building or estate, build them all into a compliance calendar or tracker with their correct legal frequencies, ensure each one is scheduled and completed on time by a competent person, and keep the certificates and records to prove compliance. Missing a statutory task — an overdue fire alarm service, a lapsed lift examination, an out-of-date Legionella assessment — is both unlawful and potentially dangerous, and it’s exactly the kind of thing that good maintenance planning exists to prevent. This is why rigorous tracking of statutory compliance is the FM priority above all else, and why CAFM systems that automatically flag statutory tasks when due are so valuable. See our Asset Inspection, Fire Safety Equipment, Emergency Lighting, and Electrical Maintenance Safety guides for detail on specific areas.
How do I build a PPM schedule?
A PPM (planned preventive maintenance) schedule is the planned calendar of all the recurring maintenance a building needs, and building one follows a logical sequence. Start with an asset register — a complete list of all the assets and systems that need maintaining, because you can’t plan maintenance for assets you haven’t identified; this is the foundation. For each asset, define the maintenance tasks and their frequencies, drawing on manufacturer recommendations, statutory requirements (which set mandatory frequencies for regulated systems), recognised standards (SFG20 is the widely-used standard for building maintenance tasks and frequencies in FM), and your own experience. Then schedule these tasks across an annual calendar, laying them out so the workload is balanced through the year and nothing is missed — making sure all the statutory inspections and servicing are built in at their legal frequencies, as these are non-negotiable fixed points. Assign responsibility for each task — deciding what the in-house team does and what specialist or statutory contractors handle. Manage the whole schedule in a system — ideally CAFM software rather than spreadsheets, so that tasks are automatically generated when due and tracked to completion. And keep the schedule under review, updating it as assets are added, removed, or changed. The result is a structured, forward-looking plan that ensures every asset gets the maintenance it needs at the right intervals, that statutory deadlines are met, and that the work is resourced and tracked rather than forgotten. A good PPM schedule is what transforms FM maintenance from reactive firefighting into a proactive, managed operation, and using a recognised standard like SFG20 as the basis for tasks and frequencies (rather than guessing) gives it a solid, defensible foundation. The asset register and the PPM schedule together are the core planning documents of an FM maintenance operation. See our Preventive Maintenance and Industrial Maintenance Checklist guides for the underlying principles.
What is the difference between hard FM and soft FM?
Hard FM and soft FM are the two broad categories of facilities management services. Hard FM refers to the physical building and its systems — the building fabric and structure, and the building services such as HVAC (heating, ventilation, and air conditioning), electrical systems, plumbing and water systems, lifts, and fire systems. It’s the maintenance, servicing, and statutory compliance of the actual building and its engineering services, and it’s largely non-discretionary — particularly the statutory elements, which legally must be done. Hard FM is what this guide primarily concerns, and it carries the bulk of the statutory compliance weight. Soft FM, by contrast, refers to the services that make the building pleasant, clean, safe, and functional to occupy — things like cleaning, security, catering, grounds and landscaping maintenance, waste management, and pest control. These services support the people using the building rather than maintaining the building’s physical systems. The distinction matters for planning and resourcing because the two categories often involve different skills, contractors, and management approaches, and hard FM carries the statutory and safety-critical obligations that must be prioritised. However, both hard and soft FM benefit from planning and scheduling — a cleaning regime or grounds maintenance programme is planned much like a PPM schedule, even though it doesn’t carry the same statutory weight as, say, lift examinations or fire alarm servicing. Many FM operations manage both, either with in-house teams, outsourced contracts, or a mix, and a total facilities management approach brings both under coordinated management. Understanding the distinction helps in organising the FM function, allocating resources and contracts appropriately, and recognising that while both need planning, hard FM — especially its statutory compliance — is where the legal and safety priorities lie. See our Facilities Cleaning & Hygiene guide for more on the cleaning side of soft FM.
Should facilities maintenance be done in-house or outsourced to contractors?
Most FM operations use a mix of in-house teams and specialist contractors, and deciding the balance depends on capability, cost, and the nature of the work. An in-house team of directly-employed FM and maintenance staff is well-suited to day-to-day maintenance, minor repairs, general upkeep, and providing responsive cover for the building’s routine needs — they know the building, they’re on hand, and they can respond quickly to reactive issues. Specialist contractors, on the other hand, are used for specialist and statutory work that requires specific qualifications, expertise, or equipment — such as lift maintenance and LOLER examination, fire system servicing, air conditioning and F-Gas work, electrical testing, and Legionella management. For statutory thorough examinations and much specialist servicing, the contractor provides the competent person that the law requires, with the necessary expertise and (for statutory examinations) independence. The decision of what to do in-house versus outsource comes down to whether you have the in-house capability and qualifications, the relative cost, the volume of work (enough specialist work to justify in-house capability, or better outsourced), and the specialist or statutory nature of the task. Whatever the mix, managing contractors well is essential: selecting competent contractors, managing them on site (including permits to work and contractor safety), checking the quality of their work, and obtaining and keeping their certificates — particularly the statutory compliance certificates that prove legal duties have been met. Contractor visits also need to be scheduled and coordinated within the overall PPM plan so they happen at the right times. The key principles are to use in-house staff for routine, responsive, general work where you have the capability, use qualified specialist contractors for specialist and statutory work, manage contractors properly (competence, permits, quality, certificates), and ensure that whatever mix you choose, you have enough resource and the right skills to actually deliver the maintenance plan. The goal is reliable, compliant maintenance delivery, achieved through whatever combination of in-house and contracted resource best fits the building and the organisation.
What is a CAFM system and do I need one?
CAFM stands for Computer-Aided Facilities Management — software that helps facilities teams manage and plan their maintenance and facilities operations, and it’s increasingly central to FM maintenance planning. A CAFM system typically holds the asset register, schedules and automatically issues planned PPM and statutory maintenance tasks when they’re due, manages reactive work orders and the helpdesk (logging, assigning, tracking, and closing jobs), tracks statutory compliance and certificates, records the complete maintenance history, helps manage contractors, and provides reporting and KPIs. Its biggest benefits for FM are the automation of scheduled tasks — so planned and statutory maintenance is generated and flagged when due, meaning nothing gets forgotten — and compliance tracking, which is hugely valuable given how critical and complex statutory compliance is for FM. Whether you need one depends on the scale and complexity of your operation. For all but the smallest FM operations, a CAFM system is strongly worthwhile because managing a complex building or estate’s maintenance — with its many assets, numerous statutory obligations at different frequencies, mix of planned and reactive work, and multiple contractors — on spreadsheets is error-prone and makes it easy for things (including statutory deadlines) to be missed. CAFM brings the structure, automation, tracking, and record-keeping needed to manage that complexity reliably. That said, the principles of good maintenance planning matter more than the specific tool — a CAFM system supports good planning but doesn’t replace the need for a proper asset register, well-defined tasks and frequencies, and the discipline to keep everything updated and acted upon. A poorly-implemented CAFM system, or one that isn’t kept up to date, won’t deliver its benefits. So for a small, simple operation a well-maintained spreadsheet or simple system might suffice, but for most FM operations of any scale, a CAFM system is a valuable and often essential tool for delivering compliant, well-planned maintenance — particularly for the all-important statutory compliance tracking. See our Reducing Equipment Downtime guide for more on CMMS/CAFM systems.
How do I stop reactive work taking over?
Reactive work crowding out planned and statutory maintenance is one of the most common and damaging problems in FM — the team gets so consumed by responding to breakdowns and requests that the planned preventive maintenance and even statutory tasks start slipping, which ironically leads to more breakdowns (because preventive work isn’t being done) and creates compliance risk. Breaking this cycle takes several deliberate measures. First and most importantly, protect time and resource for planned and statutory work — ring-fence it so it doesn’t get raided every time a reactive job comes in; statutory tasks especially must be treated as fixed, non-negotiable commitments. Second, build up the planned preventive maintenance programme, because the more effective your PPM, the fewer breakdowns you’ll have, which reduces the reactive workload over time — it’s a virtuous cycle that mirrors the vicious one, but it requires the upfront investment in planned work to get there. Third, prioritise reactive work properly using a triage system and SLAs, so genuinely urgent issues get immediate attention while less urgent ones are scheduled rather than dropping everything — not every reactive request is an emergency. Fourth, use a work-order system (ideally CAFM) to log, prioritise, and manage reactive jobs in an organised way rather than chaotically. Fifth, analyse recurring reactive jobs to find and fix root causes, so the same problems stop generating repeat reactive work (see our Reducing Equipment Downtime guide on root-cause analysis). Sixth, ensure adequate resourcing — if the team is genuinely under-resourced for the building’s needs, planned work will always lose to reactive demands, and this needs addressing. The fundamental principle is that an operation dominated by reactive work is in a self-perpetuating trap, and escaping it requires deliberately protecting and building up the planned and preventive work even while managing the reactive demands — shifting the balance over time from mostly reactive to mostly planned. Measuring the planned-versus-reactive ratio is a useful way to track progress, as a higher proportion of planned work indicates a more proactive, mature, and ultimately less stressful and less costly operation.
How should I budget for facilities maintenance?
Budgeting for facilities maintenance involves planning and forecasting the costs of the whole maintenance operation — the planned preventive maintenance, the statutory compliance work, the reactive repairs, and the maintenance contracts — and a key advantage of good maintenance planning is that it makes these costs far more predictable and controllable. A well-developed PPM schedule and known statutory obligations give you a clear picture of the recurring, planned costs across the year, which can be budgeted with reasonable confidence, while a reactive, unplanned operation faces unpredictable, often higher costs from emergency repairs and failures. So the first principle is that planned maintenance produces a more predictable and ultimately lower-cost budget than reactive firefighting. Beyond the annual running costs, facilities budgeting needs to account for lifecycle and capital planning — planning and budgeting for the eventual replacement of major plant and equipment such as boilers, chillers, lifts, and roofing, which have finite lives and will need significant capital expenditure when they reach the end of them. Lifecycle costing looks ahead to when major assets will need replacing and ensures the capital is planned for, rather than being caught out when a boiler or lift fails with no budget allocated. This forward planning is important because major plant replacement is expensive and disruptive, and planning for it avoids both financial shock and the operational crisis of a critical system failing with no replacement budget. A further aspect of FM budgeting is demonstrating the value of planned maintenance to secure the necessary funding — showing how planned and statutory maintenance delivers compliance (avoiding legal and safety risk), reduces failures and their costs, and extends asset life (deferring capital spend), which justifies the maintenance budget against pressure to cut it. Cutting planned maintenance to save money in the short term is a false economy that leads to more failures, compliance risk, and higher costs down the line. So good FM budgeting combines forecasting the predictable planned and statutory running costs, planning ahead for lifecycle capital replacement of major plant, and making the case for adequate maintenance funding based on the value it delivers. The predictability that good maintenance planning brings is itself one of its major benefits for financial management.