⚡ Generator Buying Guide — UK Sizing, Inverter vs Diesel & Safety

A UK guide to buying generators — sizing (running vs starting watts, kVA), conventional vs inverter, petrol vs diesel, single vs three-phase, prime vs standby, and CO safety.

A generator is what stands between work and a standstill when there’s no mains power — on a remote site, in a power cut, at an outdoor event, or anywhere the grid doesn’t reach. It can run tools, lighting, welding plant, pumps, and site accommodation, or keep critical systems alive when the mains fails. But generators are also among the more technical purchases a trade makes, with real consequences for getting it wrong: an undersized generator won’t start the load, an oversized one wastes fuel and money, and an incorrectly used one is a genuine carbon monoxide and electrical danger.

Buying the right generator means understanding power requirements (and the crucial difference between running and starting power), the generator types (conventional vs inverter), fuel options, single vs three-phase, the duty (prime/continuous vs standby), and the safety essentials — because generators kill, through carbon monoxide poisoning and electrocution, when used incorrectly. This is a purchase where matching the machine to the load and the application, and respecting the safety rules, matters a great deal.

This guide covers how to size a generator (running vs starting watts, kVA and power factor), conventional vs inverter generators, fuel types (petrol, diesel, dual-fuel, LPG), single vs three-phase, prime vs standby duty, the critical safety considerations (carbon monoxide, earthing, connection), noise, sector-specific selection, maintenance, and the common mistakes that cause failure or danger.

Why Generator Selection Matters

A generator that is wrongly sized or specified causes real problems: too small and it can’t start motors or runs overloaded (damaging both the generator and the connected equipment); too large and the capital cost and running cost are wasted, and it may run inefficiently (“wet stacking” on diesels run under-loaded). The wrong fuel type, phase, or duty rating leaves a machine that doesn’t suit the work. And critically, generators are a serious safety hazard: exhaust fumes contain carbon monoxide that kills in enclosed spaces, and the electrical output can electrocute if earthing and connection aren’t correct.

For UK users, generator use intersects the Electricity at Work Regulations 1989 (safe electrical systems, earthing, connection), the Health and Safety at Work Act, COSHH / confined space rules (exhaust fumes), and noise regulations. A correctly sized, correctly connected, correctly sited generator is a safe and productive tool; a mismatched or misused one is a hazard and a wasted investment.

Sizing a Generator: Running vs Starting Power

The single most important and most-misunderstood part of generator buying is sizing — and the key is understanding that many loads need far more power to start than to run.

Running (Continuous) Power

The power a load draws once it’s running steadily — the figure usually printed on the appliance. Add up the running power of everything that will run simultaneously.

Starting (Surge / Peak) Power

The much higher power some loads draw momentarily at start-up — especially anything with an electric motor (compressors, pumps, large power tools, refrigeration). A motor can draw 2–4 times (or more) its running power for a moment as it starts. The generator must be able to supply this surge, or the motor won’t start and may stall or trip the generator.

How to Size

  • List every item that will run at the same time
  • Add up their running power
  • Identify the item with the largest starting surge, and add that surge on top of the running total (typically you size for the running total plus the single largest starting requirement, since loads don’t usually all start at once)
  • Add a margin (typically 20%+) so the generator isn’t run at its absolute limit — running flat-out continuously shortens its life
  • Choose a generator whose maximum (peak) output covers the surge and whose rated (continuous) output comfortably covers the running total

kVA, kW, and Power Factor

Generator output is often quoted in kVA (kilovolt-amps, apparent power) as well as kW (kilowatts, real power). The relationship is kW = kVA × power factor (typically 0.8 for generators). So a 10 kVA generator delivers around 8 kW of real power. When sizing, work in consistent units and account for the power factor — a common error is treating kVA and kW as the same. For resistive loads (heaters, lighting, simple tools) the difference is small; for motor loads the distinction matters.

Conventional vs Inverter Generators

Conventional Generators

Run the engine at a fixed speed (typically 3000 rpm for 50 Hz UK output) to generate AC directly. Robust, powerful, and cost-effective for larger outputs. The power quality is adequate for tools, lighting, heating, and motors, but the waveform is less “clean” than an inverter’s — which can matter for sensitive electronics. They’re noisier and less fuel-efficient at part load because the engine runs at full speed regardless of demand. The standard choice for site power, larger loads, and rugged use.

Inverter Generators

Generate AC, convert it to DC, then invert it back to a very clean, stable AC waveform via electronics. Advantages: clean power safe for sensitive electronics (laptops, control systems, modern tool electronics), much quieter, more fuel-efficient (the engine varies its speed to match the load via “eco” mode), lighter and more compact for their output, and often parallel-capable (two units linked for more power). The trade-offs: more expensive per watt and generally lower maximum outputs than large conventional/diesel units. Ideal for portable, lower-power, noise-sensitive, and electronics-powering applications — events, camping, light site use, powering sensitive equipment.

Fuel Types

Petrol

Common on smaller and portable generators. Cheaper to buy, lighter, easy to start. Trade-offs: higher running cost, shorter engine life under heavy use, fuel storage and stability concerns (petrol degrades), and not ideal for prolonged continuous running. Good for portable, intermittent, lower-power use.

Diesel

The standard for larger, heavier-duty, and continuous-use generators. More fuel-efficient, longer engine life, more robust for sustained running, and diesel is safer to store than petrol. Heavier and more expensive to buy, and diesels dislike prolonged light loading (“wet stacking”). The choice for site power, prime/continuous duty, and larger outputs.

Dual-Fuel

Generators that run on petrol and LPG (or petrol and another fuel), giving flexibility — LPG burns cleaner, stores well long-term, and can be cheaper, while petrol offers convenience. Useful where fuel flexibility or long storage matters (standby use).

LPG / Gas

Cleaner-burning, long storage life (good for standby), and lower emissions. Used for standby and where clean running matters.

Single-Phase vs Three-Phase

  • Single-phase (230V): Standard for most tools, lighting, and general site equipment. The right choice unless three-phase equipment is involved.
  • Three-phase (400V): Required for three-phase motors and machinery — larger plant, some industrial equipment, certain pumps and compressors. A three-phase generator can often supply single-phase loads too, but balancing matters. Only needed where three-phase equipment is actually used — buying three-phase unnecessarily adds cost and complexity.

Prime / Continuous vs Standby Duty

Generators are rated for different duty cycles, and matching the rating to the use is essential:

  • Standby rating: For emergency backup that runs occasionally when the mains fails — a higher short-term output but not for continuous running. Suits mains-failure backup.
  • Prime / continuous rating: For generators that are the primary power source running for extended periods — a lower but sustainable output rating built for continuous duty. Suits site power and off-grid primary supply.
  • Running a standby-rated machine continuously, or a prime machine beyond its continuous rating, shortens its life and risks failure. Match the duty rating to how the generator will actually be used.

Critical Safety Considerations

Generators cause deaths every year through two main hazards — both entirely preventable.

Carbon Monoxide (CO) — The Silent Killer

Generator exhaust contains carbon monoxide, a colourless, odourless, lethal gas. Generators must NEVER be run indoors, in garages, in tents, in site cabins, or in any enclosed or partially-enclosed space — even with doors or windows open. CO builds up rapidly and kills. Generators must run outdoors, well away from windows, doors, vents, and air intakes, with the exhaust directed away from occupied areas. This is the single most important generator safety rule, and CO poisoning from generators is a recurring cause of fatalities.

Electrical Safety, Earthing, and Connection

  • Earthing: Generators must be correctly earthed per the manufacturer’s instructions and the application — incorrect earthing creates electrocution risk. Earthing requirements vary with the generator type and setup; competent advice is needed for anything beyond simple portable use.
  • Connection to building wiring: Connecting a generator to a building’s fixed wiring (for backup power) MUST be done through a proper changeover switch (transfer switch) installed by a competent electrician — never by “back-feeding” through a socket, which is illegal, lethal to anyone working on the supposedly-dead mains (including utility workers), and a fire risk.
  • RCD protection: Use RCD protection on outputs as appropriate.
  • Cables and connections: Use suitable, undamaged cables rated for the load; keep connections dry.
  • Competent setup: Anything beyond plugging tools directly into a portable generator’s outlets needs competent electrical advice.

Other Safety

  • Fuel handling: Refuel a stopped, cooled generator — never a running or hot one (fire risk). Store fuel safely.
  • Hot surfaces: Exhaust and engine get very hot — burn risk.
  • Siting: On firm level ground, protected from weather (but ventilated), away from combustibles.
  • Fumes and air intakes: Keep exhaust away from building air intakes and downwind of people.

Noise

Generators are noisy, and noise matters for events, residential areas, and prolonged site use. Considerations: inverter generators are much quieter than conventional; “silenced” or canopied diesel generators have sound-attenuating enclosures for lower noise; the noise level (dB(A) at a stated distance) is a published spec to compare; and siting away from people and using the eco/economy mode (inverters) reduces noise. For events and noise-sensitive locations, a quiet inverter or silenced generator is often essential.

Other Features to Consider

  • Run time / tank size: How long it runs per tank at a given load — important for unattended and long-duration use.
  • Electric vs recoil start: Electric (key/button) start for convenience on larger machines; recoil (pull) start on smaller ones.
  • Automatic start (AMF — Auto Mains Failure): For standby generators that start automatically when the mains fails.
  • Outlets: The number and type of sockets (110V site outlets, 230V, 400V three-phase, USB).
  • 110V site output: For construction-site tools that run on 110V — some generators provide 110V outlets directly.
  • Portability: Wheels, frame, handles, and weight for moving around site.
  • Fuel gauge, hour meter, and low-oil shutdown: Useful monitoring and protection features.
  • Parallel capability: Linking two inverter units for more power.

Sector-Specific Selection

Construction Sites

Diesel prime-rated generators sized to the site load, often with 110V outlets for site tools, robust and weatherproof, sized with surge headroom for compressors and large tools.

Events / Outdoor Functions

Quiet inverter or silenced diesel generators, clean power for electronics and lighting, sized for the load with margin, noise a key consideration.

Agriculture / Rural

Diesel generators for prime power and equipment, three-phase where farm machinery needs it, robust for the environment, often PTO or standby options.

Backup / Standby (Premises)

Standby-rated generators, often with auto-start (AMF) and a professionally-installed changeover switch, diesel or LPG, sized for the critical loads.

Market Traders / Mobile Catering

Quiet inverter generators, clean power, sized for the appliances (watch the starting surge of fridges and equipment), low noise for pitches.

Off-Grid / Remote Work

Diesel for fuel efficiency and continuous running, robust build, adequate run time, sized for the tools and lighting.

Powering Sensitive Electronics

Inverter generators for the clean, stable waveform that protects laptops, control systems, and modern electronics.

Welding

Dedicated welding generators or generators sized for the welder’s substantial surge and output requirements.

Maintenance

  • Regular oil changes per the engine schedule (and an initial run-in oil change on new engines)
  • Air filter cleaning / replacement
  • Fuel system care — use fresh fuel, fuel stabiliser for stored petrol, drain old fuel
  • Run standby generators regularly under load to keep them ready and avoid problems
  • Avoid prolonged light loading of diesels (wet stacking) — load them adequately
  • Check and maintain the battery on electric-start machines
  • Keep cooling air paths clear; don’t overheat
  • Spark plug service (petrol)
  • Store with fuel system appropriately prepared for the storage period
  • Keep clean, dry, and protected when stored

Common Mistakes

Ignoring Starting Surge

Sizing only for running power and finding the generator can’t start a motor (compressor, pump). Always account for the starting surge of motor loads, which can be several times the running power.

Running a Generator Indoors

The deadliest mistake — running a generator in a garage, cabin, tent, or enclosed space causes fatal carbon monoxide poisoning. NEVER run a generator anywhere but well-ventilated outdoor space, exhaust directed away from people and air intakes.

Back-Feeding the Mains

Connecting a generator to building wiring through a socket (“back-feeding”) instead of a proper changeover switch — illegal, a fire risk, and potentially lethal to anyone (including utility workers) on the supposedly-dead mains. Always use a competent electrician and a transfer switch.

Confusing kVA and kW

Treating a 10 kVA generator as 10 kW — it delivers around 8 kW (kVA × 0.8 power factor). Size in consistent units accounting for power factor.

Wrong Duty Rating

Running a standby-rated generator continuously, or pushing a prime machine beyond its continuous rating — shortening its life. Match the duty rating to the use.

Oversizing

Buying far more generator than needed — wasting capital and fuel, and (on diesels) risking wet stacking from light loading. Size with sensible margin, not massive excess.

Incorrect or No Earthing

Failing to earth the generator correctly — an electrocution risk. Follow the manufacturer’s earthing instructions and get competent advice for anything beyond simple portable use.

Refuelling Hot or Running

Adding fuel to a running or hot generator — a serious fire risk. Stop and cool before refuelling.

Conventional Generator for Sensitive Electronics

Powering laptops or sensitive control systems from a conventional generator’s less-clean output, risking damage. Use an inverter generator for sensitive electronics.

Neglecting Maintenance

Stale fuel, no oil changes, standby units never run — leading to a generator that won’t start when needed. Maintain and exercise generators regularly.

Conclusion

A generator is a powerful, productive tool and a serious responsibility. Buying the right one starts with correct sizing — accounting for starting surge as well as running power, and understanding kVA vs kW — then choosing the type (conventional for robust larger loads, inverter for clean power, quiet running, and electronics), the fuel (diesel for continuous heavy duty, petrol for portable intermittent use), the phase (single unless three-phase equipment demands otherwise), and the duty rating (prime for primary supply, standby for backup) to match the work.

What separates safe, productive generator use from danger and disappointment is sizing it correctly for the actual load including surge, matching the type and duty to the application, and — above all — respecting the safety rules: never run it indoors or in any enclosed space (carbon monoxide kills), earth it correctly, connect to building wiring only through a competent electrician’s changeover switch, and refuel only when stopped and cool. Get the sizing and the safety right, and a generator reliably keeps the work going wherever the mains doesn’t reach — which is exactly what it’s for.

Frequently Asked Questions

How do I work out what size generator I need?

List every item that will run at the same time and add up their running (continuous) power — the figure usually printed on each appliance. Then identify the item with the largest starting surge (motor-driven equipment like compressors, pumps, and large tools can draw 2–4 times their running power momentarily at start-up) and add that surge on top of the running total, since loads don’t usually all start at once. Add a margin of around 20% or more so the generator isn’t run at its absolute limit. Choose a generator whose maximum (peak) output covers the surge and whose rated (continuous) output comfortably covers the running total. The most common sizing mistake is ignoring the starting surge and ending up unable to start motors.

What’s the difference between running watts and starting watts?

Running (or continuous) watts is the power a load draws once it’s running steadily — this is the figure usually quoted on appliances. Starting (or surge/peak) watts is the much higher power some loads draw momentarily as they start up, particularly anything with an electric motor: compressors, pumps, refrigeration, and large power tools can draw two to four times (sometimes more) their running power for a moment at start-up. The generator must be able to supply this surge, or the motor simply won’t start and may stall the generator or trip it. This is why you size a generator to handle the running total plus the largest single starting surge — sizing on running power alone is the classic mistake that leaves you with a generator that can’t start your equipment.

What’s the difference between conventional and inverter generators?

Conventional generators run the engine at a fixed speed to generate AC directly — they’re robust, powerful, and cost-effective for larger outputs, but noisier, less fuel-efficient at part load (the engine runs full speed regardless of demand), and produce a less “clean” power waveform. Inverter generators generate AC, convert it to DC, then electronically invert it back to a very clean, stable AC waveform — they’re much quieter, more fuel-efficient (the engine varies speed to match the load), lighter and more compact, and produce clean power safe for sensitive electronics, but cost more per watt and generally have lower maximum outputs. Choose conventional/diesel for robust larger site loads, and inverter for portable, quiet, fuel-efficient use and powering sensitive electronics like laptops and control systems.

Why must I never run a generator indoors?

Because generator exhaust contains carbon monoxide (CO) — a colourless, odourless, lethal gas that builds up rapidly in enclosed spaces and kills. Generators must NEVER be run indoors, in garages, in tents, in site cabins, or in any enclosed or partially enclosed space, even with doors or windows open, because CO accumulates faster than ventilation can clear it. This is the single most important generator safety rule, and CO poisoning from generators causes deaths every year. Always run a generator outdoors, well away from windows, doors, vents, and air intakes, with the exhaust directed away from any occupied areas and downwind of people. The danger is invisible and gives no warning, which is exactly why the rule is absolute.

Can I connect a generator to my building’s wiring?

Only through a proper changeover (transfer) switch installed by a competent electrician — never by “back-feeding” through a socket. Back-feeding (plugging the generator into a socket to power the building) is illegal, a fire risk, and potentially lethal: it energises the building’s wiring and can send power back out to the mains network, electrocuting utility workers or anyone working on what they believe is a dead supply. A changeover switch safely isolates the building from the mains before connecting the generator, so the two power sources can never be connected at once. Any connection of a generator to fixed building wiring must be designed and installed by a competent electrician in accordance with the wiring regulations — this is not a DIY job.

What’s the difference between kVA and kW on a generator?

kVA (kilovolt-amps) is apparent power and kW (kilowatts) is real power — the usable power that actually does work. They’re related by the power factor: kW = kVA × power factor, and generators typically have a power factor of 0.8. So a generator rated at 10 kVA delivers around 8 kW of real power. A common and costly mistake is treating kVA and kW as the same number when sizing — which leaves you about 20% short. When sizing, work in consistent units and account for the power factor. For purely resistive loads (heaters, incandescent lighting, simple tools) the practical difference is small, but for motor loads and mixed loads the distinction genuinely matters, so always check whether a rating is quoted in kVA or kW.

Petrol or diesel generator — which should I choose?

Petrol generators are common on smaller, portable units — cheaper to buy, lighter, and easy to start, suiting portable, intermittent, lower-power use. Their trade-offs are higher running costs, shorter engine life under heavy use, fuel that degrades in storage, and unsuitability for prolonged continuous running. Diesel generators are the standard for larger, heavier-duty, and continuous-use machines — more fuel-efficient, longer engine life, more robust for sustained running, and diesel stores more safely than petrol. They’re heavier and cost more to buy, and dislike prolonged light loading (“wet stacking”). Choose petrol for portable, occasional, lower-power needs; choose diesel for site power, prime/continuous duty, and larger outputs. Dual-fuel (petrol/LPG) and LPG options add flexibility and clean, long-storage running for standby use.

What’s the difference between prime and standby generator ratings?

The duty rating tells you how the generator is designed to be used. A standby rating is for emergency backup that runs only occasionally when the mains fails — it offers a higher short-term output but isn’t built for continuous running. A prime (or continuous) rating is for a generator that serves as the primary power source running for extended periods — a lower but sustainable output rating built for continuous duty. Matching the rating to the use is essential: running a standby-rated machine continuously, or pushing a prime-rated machine beyond its continuous rating, overworks it and shortens its life or causes failure. For site power and off-grid primary supply, choose a prime/continuous-rated generator; for mains-failure backup, a standby-rated machine (often with auto-start) is appropriate.

Suggested Products

⚡ Inverter Generators⚡ Conventional Petrol Generators⛽ Diesel Generators🔆 Silenced / Canopied Diesel Generators🔁 Dual-Fuel Generators (Petrol/LPG)🏭 Three-Phase Generators🏗️ Site Generators (110V Output)🔌 Standby Generators (Auto-Start / AMF)⚡ Welding Generators🔋 Portable Power Stations🔌 Changeover / Transfer Switches🔌 Generator Cables & Connectors⛽ Jerry Cans & Fuel Stabiliser🛢️ Generator Oil & Service Kits☂️ Generator Covers & Tents🚨 Carbon Monoxide Alarms