⚡ Mobile Power Generators Guide for Location — UK Film, Event & Outdoor Production
A UK guide to mobile power for film and location work — LiFePO4 battery power stations, inverter and hybrid systems, silenced generators, BS 7909 distribution, RCD/RCBO, earthing, fuel and battery safety, and noise compliance.
Mobile power is the lifeblood of any UK location production. Film and TV crews, outside broadcast teams, event productions, construction-site operations, agricultural contractors, and emergency response units all rely on portable power to deliver clean, safe electricity where mains supply is absent, inadequate, or impractical. A well-specified power setup is invisible — it just works. A badly-specified one becomes the production’s single biggest constraint, with knock-on impacts on shooting time, sound quality, electrical safety, and crew morale.
The mobile power landscape has changed significantly. For sound-critical and lower-draw work, battery power stations — increasingly built on LiFePO4 (lithium iron phosphate) cells — and inverter generators now lead the field, offering silent or near-silent operation and clean power that older engine-driven sets struggle to match. Engine generators (diesel, petrol, and gas) remain essential for sustained high loads and long-duration work, but they are now one option among several rather than the automatic default. Choosing well means starting from the load and the noise requirement, not from the assumption that “generator” means “diesel.”
UK power selection sits at the intersection of three considerations: matching output to load with appropriate headroom, complying with BS 7909 distribution and earthing for entertainment use, and — critically for film and TV — meeting acoustic requirements so dialogue recording is possible. A battery station running silently, or a silenced unit at 58 dB, makes a scene shootable where a standard construction-grade generator at 75 dB is unusable. This guide covers the categories of mobile power in current UK use — battery and inverter first — the calculation of power requirements with realistic safety margins, BS 7909-compliant distribution and earthing, fuel handling, noise compliance, safety distances, and the common mistakes that turn a location shoot into a power-management problem.
Why Mobile Power for Location Production
UK location work routinely operates beyond the reach of adequate mains supply:
- Rural and remote locations with no nearby supply
- Urban locations where mains tie-ins are impractical or unauthorised
- Locations where the available mains is insufficient for production load
- Where production requires electrical isolation from the host building
- Where sound recording is incompatible with the host building’s mechanical / electrical noise
- Outdoor or wet locations where temporary mains installation is impractical
- Construction sites in early phases before permanent supply
- Live events, festivals, and outdoor performances
- Emergency response and disaster recovery operations
For each, a properly-specified mobile power source with BS 7909 distribution provides the same quality and safety of supply as a permanent installation, with the additional advantages of portability, isolation, and predictable capacity.
Types of Mobile Power
Battery Power Stations (LiFePO4 / Lithium)
Battery power stations have moved from a niche accessory to a primary power source for a large share of UK location work, and the shift is being driven by LiFePO4 (lithium iron phosphate) battery chemistry. A battery station is a large rechargeable battery bank with a built-in inverter delivering clean 230V (and, in larger units, three-phase) output — with no engine, no fuel, no exhaust, and no noise.
LiFePO4 is now the chemistry of choice for professional mobile battery power, and for good reasons. Compared with the older lithium chemistries (such as NMC) used in consumer power banks, LiFePO4 offers:
- Far greater cycle life: Typically 3,000–6,000+ full charge/discharge cycles — often several times the life of NMC — so a professional unit lasts years of daily use rather than degrading quickly.
- Superior thermal stability and safety: LiFePO4 is markedly more resistant to thermal runaway than NMC/lithium-cobalt chemistries, which matters greatly for kit run near crew, in vehicles, and in enclosed spaces.
- Stable output across the discharge curve: Holding voltage well as it discharges, delivering consistent power.
- Tolerance of frequent partial charging and a wide usable depth of discharge.
- No fumes and silent operation — making it usable literally on set, beside the camera, or indoors.
For UK production this means a LiFePO4 station is ideal for sync-sound dialogue scenes (zero noise), interview and documentary setups, LED-lit shoots, camera and monitoring power, comms and DIT carts, photography, and any low-to-moderate continuous draw. Capacities for hire now span roughly 1 kWh portable units up to 5–80 kWh trailer and cart systems, with the larger banks powering substantial setups for hours. Their clean inverter sine wave (see below) is excellent for sensitive electronics. The trade-off is finite stored energy — a battery runs until depleted — so for sustained heavy loads they are either sized generously, swapped, or paired with an engine generator in a hybrid arrangement (below).
Inverter Generators
Inverter generators are the natural companion to battery stations and the other clean-power option to reach for first. They use electronic inverter technology to produce a far cleaner sine wave than conventional alternators — critical for sensitive electronics, computer equipment, broadcast gear, and any modern lighting with electronic ballasts or LED drivers. Look for Total Harmonic Distortion (THD) under 3% for production-grade clean power. Most modern small petrol generators and many silenced diesels are now inverter type, and inverter petrol units in the 2–10kVA range are a common small-scale choice. Many inverter units also offer eco/variable-speed modes that cut fuel use and noise at light load. Battery stations and inverter generators together cover the clean, quiet end of the market — and frequently co-exist on the same production, the battery handling sound-critical periods and the inverter generator extending runtime or recharging the bank.
Hybrid Battery + Generator Systems
Hybrid systems combine a LiFePO4 battery bank with an engine generator that charges it, giving the best of both: silent battery power during sound-critical takes, with the generator cutting in (often automatically, when the battery reaches a set level) to recharge during noisy periods or breaks. This dramatically reduces fuel consumption, run hours, noise, and emissions versus running a generator continuously — the generator only runs when needed, at its most efficient load point, rather than idling against a light draw all day. Hybrids are increasingly the standard approach for environmentally-conscious and sound-sensitive UK productions, and for long-duration events where they slash fuel costs.
Silenced Diesel Generators
Where sustained higher loads are needed — substantial lighting packages, larger drama and broadcast setups — silenced diesel generators remain a mainstay. Specifically engineered for low acoustic output, multi-stage exhaust silencing, an enclosed acoustic canopy, and vibration isolation reduce noise to around 55–65 dB at 1 metre — quiet enough for sync sound dialogue recording, though not silent like a battery. Outputs run from around 10kVA to 80kVA+ per location, they sustain heavy loads indefinitely given fuel, and many are inverter type for clean output. Hire rates are typically 20–40% higher than equivalent standard diesel. They are the established choice for larger sound-critical productions where the load exceeds what a battery bank can comfortably sustain.
Standard / Open-Frame Diesel Generators
The robust, long-lived, fuel-efficient option for UK construction and outdoor industrial work where noise is not a constraint. Available in outputs from 5kVA to 500kVA+, with higher capital cost than petrol but lower running cost. Acoustic output of 70–85 dB at 1 metre makes them unsuitable for sound recording, but they are well-suited to construction sites, site huts, power tools, and heavy outdoor loads run around the clock.
Petrol Generators
Lighter and lower in capital cost, with shorter run-time per fuel load. Common in the 2kVA to 10kVA range (frequently inverter type). Suitable for small-scale or short-duration work — corporate shoots, small documentary, photography, light agricultural — though with higher running cost than diesel and shorter generator life under sustained use.
Gas / LPG / Bi-Fuel
Specialty units running on natural gas, LPG, or switchable fuel. Lower emissions and quieter than petrol, used where fuel-storage rules or environmental considerations favour gas.
Choosing Between Them
- Start with noise: If the period is sound-critical, reach for a battery station (silent) or, for larger sustained loads, a silenced or hybrid unit — never a standard open-frame generator.
- Then the load and duration: Low-to-moderate draw for hours → LiFePO4 battery. Sustained heavy load all day → silenced diesel or hybrid. Heavy load where noise doesn’t matter → open-frame diesel.
- Clean power for electronics: Battery stations and inverter generators both deliver low-THD output; prefer them for broadcast, computing, and LED-driver loads.
- Environmental and access constraints: Battery and hybrid win on emissions, fuel storage, and indoor/urban use.
- Combine sources: It is normal and efficient to run a battery station alongside an inverter or hybrid generator on the same job, matching each to the moment.
Outputs and Phase Configuration
- Single-phase 230V: 1–20kVA. Most UK location and small site work, and the range most battery stations cover.
- Three-phase 400V: 20–500kVA+. Larger productions, industrial sites, OB units (and larger battery/hybrid systems).
- Dual output: Many units provide both single-phase and three-phase outputs from the same source.
Calculating Power Requirements
Specification starts with realistic load calculation. For battery stations, you also size the stored energy (kWh) to the runtime needed, not just the instantaneous output (kW/kVA). UK best practice:
Step 1: List All Connected Loads
Every fixture, ballast, motor, computer, monitor, refrigeration unit, and tool that will be powered. Note manufacturer’s wattage at start-up and at sustained operation — they differ significantly for motor and ballast loads.
Step 2: Calculate Simultaneous Maximum Load
Not everything runs at once. Identify which loads run simultaneously at maximum draw. This is your peak load.
Step 3: Add Start-Up Headroom
Inductive loads (motors, transformers, some ballasts) draw 2–6x their running current at start-up for fractions of a second. Add headroom accordingly — and check a battery station’s surge/peak output rating covers it.
Step 4: Add Operational Headroom
Add 20–25% to the peak load to allow for measurement error, last-minute kit changes, and reduced capacity in extreme heat or altitude.
Step 5: Size Output and (for Battery) Energy
Generator output is rated in kVA (apparent power) not kW (real power). For lighting and resistive loads, kVA ≈ kW; for motors and inductive loads, kVA ≈ kW / 0.8. For a battery station, also divide the total energy you need (average kW × hours of runtime) by the usable battery capacity to confirm the kWh bank is large enough — or plan swaps / hybrid charging.
Example
Small drama location: 1.2kW HMI key + 575W HMI fill + 4× 500W LED panel + 1kW practicals + 800W camera / monitors = 5.5kW. With 25% headroom: 6.9kW. For a sound-critical interior, a LiFePO4 battery station of ~10kVA output and sufficient kWh (e.g. a 10–15 kWh bank for a couple of hours of this draw) runs the scene silently; for a full day at this load, specify a 10kVA silenced or hybrid unit, or a larger / swappable battery system.
BS 7909-Compliant Distribution
Output — whether from a battery station, inverter, or diesel set — flows into a distribution system that must comply with BS 7909 for entertainment use:
Distribution Boards
Industry-standard “mains box” or “distro” with MCBs (Miniature Circuit Breakers) on each circuit, an overall MCB or isolator, and an RCD (Residual Current Device) protecting all socket-outlet final circuits. Common configurations: 32A in to 4×16A out, 63A in to 6×32A out, 125A three-phase in to mixed single-phase / three-phase out.
RCD Protection
30mA RCD on all socket-outlet final circuits. Fast trip (≆40ms at 30mA) protects against electric shock. BS 7909 mandates RCD protection for all entertainment temporary installations — this applies to battery-station output just as to engine generators.
Cables
Flexible mains cables sized to the load and length. H07RN-F rubber-jacketed cable is standard. Voltage drop must remain within 5% at full load — long runs require larger cable.
Connectors
16A or 32A Ceeform / Commando blue connectors for single-phase. Red five-pin for three-phase. Powercon for lighting fixtures where rated. 13A BS 1363 for low-draw equipment only.
Inspection and Testing
Before energising, the temporary installation must be inspected and tested by a competent person. Earth continuity, polarity, insulation resistance, RCD trip current and time, and prospective short circuit current all verified.
Earthing Systems
The power source and its distribution must have a properly-configured earth. The earthing arrangement applies to battery and hybrid systems as well as engine generators.
TT (Earth via Earth Electrode)
An earth electrode (rod) driven into the ground at the source location. The most common UK temporary installation. Earth resistance must be measured and verified (typically requires under 200 ohms).
TN-S (Earth via Source Bond)
Earth provided through the unit’s own bonding to the alternator/inverter neutral. Used where electrode installation is impractical.
IT (Isolated)
No fixed earth reference. Used in specialised applications. Requires insulation monitoring rather than RCD as the primary protection.
Earthing system choice must match the equipment connected and the operational requirements. Selecting the wrong system or failing to test it is a recurring UK production fault that occasionally becomes an incident.
Fuel Storage and Handling
Where engine generators are used, diesel and petrol fuel storage on UK sites is regulated by the Dangerous Substances and Explosive Atmospheres Regulations 2002 (DSEAR) and the Health and Safety (Safety Signs and Signals) Regulations 1996. (Battery stations, of course, remove this requirement entirely — one of their practical advantages.)
- Fuel stored in approved containers with appropriate labelling
- Storage location away from ignition sources and crew workspace
- Bunded storage where the quantity exceeds threshold limits
- Fire extinguisher (CO2 or dry powder) readily accessible
- Refuelling only with the generator switched off and cool
- No smoking within 3 metres of fuel storage or refuelling
- Spill kit on site with absorbent material
- Fuel quality and age managed — stale diesel and contaminated fuel are common causes of generator failure
Battery Safety and Care
LiFePO4 stations are very safe — their thermal stability is a key reason the chemistry dominates professional use — but a few practices keep them performing and safe:
- Use the supplied / specified charger and follow the manufacturer’s charging guidance; the unit’s battery management system (BMS) protects the cells.
- Operate and store within the rated temperature range — LiFePO4 tolerates a wide range but charging in very cold conditions should follow the maker’s limits.
- Don’t exceed the surge/peak output rating — size the unit for start-up loads.
- Keep ventilation around the unit as specified, and avoid physical damage to the casing and cells.
- Charge before storage to the recommended level and recharge periodically during long storage.
- Damaged units (impact, swelling, fault codes) taken out of use and handled per the manufacturer.
Noise Compliance
Power-source noise must be managed for both crew protection and the surrounding environment — a problem that battery and hybrid systems largely eliminate.
Crew Protection (Noise at Work Regulations 2005)
If a generator runs above 80 dB(A) at typical working positions, hearing protection requirements engage. Standard open-frame diesel generators at 75–85 dB will trigger this; silenced film units at 55–65 dB generally do not; battery stations are silent.
Environmental Noise
Local authority planning conditions, the Environmental Protection Act 1990, and the Control of Pollution Act 1974 may apply to night-time or sensitive-area operations. Battery, hybrid, and silenced units, acoustic enclosures, and careful site placement reduce environmental impact. For overnight operations, agreement with the local authority is advisable.
Production Sound Quality
For film and TV, generator noise within the audio capture range (typically 200Hz–8kHz at dialogue level) makes scenes unusable. Battery stations remove the problem entirely; where an engine set is used, specify silenced units, position 30m+ from set, and manage direction of arrival. Wind-blown generator noise can travel hundreds of metres.
Safety Distances
- Minimum 2 metres from buildings, vehicles, or other equipment (engine sets)
- Minimum 1 metre clear airflow space around an engine generator on all sides
- Exhaust directed away from crew, accommodation, and air intakes
- Refuelling area separated from primary crew workspace
- Fire extinguisher within 5 metres of generator location
- Trip hazards (fuel hoses, distribution cables) managed with covers or routing
- Carbon monoxide — NEVER operate a fuel-burning generator indoors or in enclosed spaces without specific engineered ventilation (battery stations produce no CO and can be used indoors)
Weather Protection
Outdoor power sources need protection from rain, wind, and snow without compromising ventilation:
- Manufacturer-supplied weather canopy where available
- IP-rated outdoor power distribution and cabling
- Cable entries sealed or routed downward to shed water
- Sufficient airflow maintained for radiator (engine) or inverter cooling
- Snow and ice managed off air intakes
- Battery units kept within their rated temperature and protected from water ingress to their IP rating
- Lightning protection in exposed locations
Sector Applications
Film and TV Drama
LiFePO4 battery stations for sync-sound interiors and LED setups; silenced diesel or hybrid for larger sustained lighting loads. Often a battery plus a silenced/hybrid unit on the same location. Production hires a competent Genny Op.
Broadcast / OB
Vehicle-mounted or trailer generators, often 100kVA+, three-phase distribution to OB trucks; battery and hybrid systems increasingly used to cut noise and emissions. Highly regulated by network safety requirements.
Music / Festival
Multiple generators, often hot-swappable for redundancy, with battery/hybrid systems increasingly deployed to cut fuel and noise. 100kVA to several MVA total. Sound, lighting, vendor power separate.
Construction Sites
Open-frame diesel, robust, used 24/7 for site huts, power tools, lighting. 10–100kVA range typical; battery units for quieter or indoor tasks.
Outdoor Events / Catering
Quiet diesel, hybrid, or battery for amenity power. Fuel-efficient operation matters for multi-day events — where hybrids cut costs sharply.
Emergency Response
Rapid-deployment generators and battery stations, often with integrated distribution. Critical reliability requirements.
Agriculture
Tractor PTO-driven or stand-alone diesel for remote operations, with battery stations for lower-draw and quieter tasks. Often dual-use (irrigation, refrigeration, lighting).
Common Mistakes
Underspecified Power Source
The most common UK production failure. The unit trips or the battery depletes under load, costing hours of shoot time. Always size output (and, for battery, stored kWh) with proper headroom — the hire-rate difference is trivial against an aborted scene.
Standard Generator for Sound Work
A standard open-frame diesel destroys boom microphone recording. Specify a battery station, or a silenced/hybrid unit, for any sync sound production.
Battery Too Small for the Runtime
Choosing a battery station on output alone and running out of stored energy mid-shoot. Size the kWh to the runtime, plan swaps, or run a hybrid that recharges the bank.
Domestic Cabling and Distribution
Plugging multiple 13A extension leads from an outlet is not BS 7909 compliance — this applies to battery stations too. Proper distribution boards with MCBs and RCD are mandatory for entertainment use.
No Earth Test
Earth electrode installed but not measured. If resistance is too high, the RCD may not trip on fault. Pre-energisation testing by a competent person is mandatory.
Fuel Storage Inadequate
Stale diesel, contaminated fuel, and unprotected fuel containers are recurring causes of generator failure and fire incidents.
CO Inside Buildings
Fuel-burning generators run inside garages, tents, or partial enclosures cause carbon monoxide poisoning — UK fatalities every year. Never operate them in enclosed spaces; use a battery station indoors instead.
Cable Voltage Drop Ignored
Long runs of undersized cable cause significant voltage drop at the load. Lights run dim, motors stall, electronics misbehave. Calculate voltage drop or use appropriately oversized cable.
No Genny Op for Larger Productions
UK insurance and BECTU practice expect a competent Genny Op for any meaningful power setup. Skipping this role to save cost transfers responsibility — and liability — to crew unqualified to manage it.
Conclusion
UK mobile power for location production is a well-developed category, and its centre of gravity has shifted. LiFePO4 battery stations and inverter generators now lead for sound-critical and lower-draw work — silent or near-silent, clean, fume-free, and increasingly capable — with hybrid battery-plus-generator systems offering the best of both worlds for sound-sensitive and long-duration jobs. Engine generators remain essential where sustained heavy loads or long unattended runtime are needed: silenced diesel for larger sound-critical setups, robust open-frame diesel for construction, and petrol or gas for small-scale or specialist use. The whole range sits within a BS 7909-compliant distribution and earthing framework refined over decades.
What distinguishes productions that get this right is rarely the hardware — it is the discipline of starting from the noise requirement and the load, choosing battery or hybrid where sound and emissions matter, calculating load (and stored energy) with proper headroom, distributing through a proper BS 7909 distro, earthing correctly and testing the earth, managing fuel and batteries safely, and hiring a competent Genny Op. Get those right and mobile power becomes invisible — just the thing that lets the production happen. Get them wrong and it becomes the production’s biggest problem on the busiest day.
Frequently Asked Questions
Are battery power stations good enough to run a film shoot?
For a large and growing share of UK location work, yes — battery power stations, especially those built on LiFePO4 (lithium iron phosphate) cells, are now a primary power source rather than a backup. Their decisive advantage is silent operation, which makes them ideal for sync-sound dialogue scenes, interviews, documentary, LED-lit setups, camera and monitoring power, comms, and DIT carts — anywhere a running engine would ruin the sound or can’t be placed. They deliver a clean inverter sine wave that suits sensitive electronics, produce no fumes (so they can be used indoors and right beside the camera), and remove fuel storage and refuelling entirely. The one thing to plan for is stored energy: a battery runs until it’s depleted, so you size the unit’s capacity in kWh to the runtime you need (average load in kW multiplied by hours), not just its instantaneous output. For low-to-moderate continuous draw over a few hours, a suitably-sized LiFePO4 station covers it comfortably; for a full day at heavy load, you either choose a larger or swappable battery system, or run a hybrid that recharges the bank from a generator during noisy periods. In practice, many UK productions run a battery station for the sound-critical takes alongside a silenced or hybrid generator for sustained load — the two co-exist naturally. So battery stations are absolutely good enough to run a shoot; the skill is matching their stored capacity to the job.
Why is LiFePO4 (lithium iron phosphate) the preferred battery chemistry?
LiFePO4 has become the chemistry of choice for professional mobile battery power for several concrete reasons over older lithium chemistries such as NMC (used in many consumer power banks). First, cycle life: LiFePO4 typically delivers around 3,000–6,000 or more full charge/discharge cycles, often several times the life of NMC, so a professional unit withstands years of daily charging and discharging rather than degrading quickly — which matters enormously for hire stock and owned kit alike. Second, and critically, thermal stability and safety: LiFePO4 is markedly more resistant to thermal runaway than lithium-cobalt and NMC chemistries, making it far safer to run near crew, inside vehicles, and in enclosed or indoor spaces — exactly where location power often lives. Third, it holds its voltage well across the discharge curve, delivering stable, consistent output rather than sagging as it empties. Fourth, it tolerates frequent partial charging and a wide usable depth of discharge, which suits the stop-start reality of a shoot day. And like all battery power, it runs silently and produces no fumes. The trade-offs are that LiFePO4 is slightly heavier and less energy-dense by volume than NMC, but for professional mobile power the gains in lifespan and safety far outweigh that. This is why hire companies and manufacturers have standardised on LiFePO4 for serious location battery systems, and why it’s worth specifically asking for it rather than a generic “lithium” unit.
What is a hybrid battery-generator system?
A hybrid system pairs a LiFePO4 battery bank with an engine generator that charges it, and it has become an increasingly standard approach for sound-sensitive and environmentally-conscious UK productions. The way it works is that the battery supplies the load silently most of the time — ideal during sync-sound takes — and the generator only starts (often automatically, when the battery falls to a set state of charge) to recharge the bank, typically during noisy periods, breaks, or overnight. Because the generator runs only when needed and then at its most efficient load point, rather than idling all day against a light draw, a hybrid dramatically cuts fuel consumption, engine run-hours, noise, and emissions compared with running a conventional generator continuously. For sound, it means you get long silent stretches for dialogue with the security of generator backing for sustained or heavy loads. For long events and multi-day jobs, the fuel and servicing savings can be substantial. The trade-off is a more complex (and often larger) system to specify and manage, but for productions that need both quiet operation and sustained capacity, hybrids genuinely offer the best of both worlds — the silence and cleanliness of battery power with the endurance of an engine generator. They sit naturally between pure battery stations (best for shorter or lower-draw silent work) and standalone generators (best for sustained heavy load where noise doesn’t matter).
What size generator do I need for a film shoot?
It depends on the production. A small interview shoot with three LED panels, camera, and monitors might need 3–5 kVA — well within a LiFePO4 battery station’s range. A drama location with HMI key, LED fills, and ancillary loads typically needs 10–20 kVA. A larger production with multiple HMIs and substantial grip load can run to 40–80 kVA. Always calculate maximum simultaneous load (lights + camera + sound + ancillary), add 20–25% headroom, and specify output in kVA — and for a battery station, also size its stored energy in kWh to the runtime you need. Underspecification (output or, for batteries, capacity) is the most common UK production power failure.
What is a silenced or whisper-quiet generator?
A diesel generator specifically engineered for low acoustic output, used for film and TV location work where sync sound recording is happening and the load is too high or too sustained for a battery station alone. Multi-stage exhaust silencing, an enclosed acoustic canopy, and vibration isolation reduce noise to around 55–65 dB at one metre, compared to 70–85 dB for standard open-frame diesel generators — quiet, though not silent like a battery. Hire rates are 20–40% higher than standard diesel. For the quietest possible operation, productions increasingly pair or replace silenced sets with battery and hybrid systems.
What does BS 7909 cover?
BS 7909 is the UK standard for temporary electrical systems used in entertainment — film, TV, music, festivals, theatre, exhibition, and similar. It covers distribution requirements, RCD protection, earthing systems, cable management, connector standards, and inspection / testing of temporary installations before they are energised — and it applies regardless of whether the source is a battery station, an inverter, or a diesel generator. UK productions of any meaningful scale should be operating to BS 7909, with a competent person responsible for the installation. Insurance and HSE practice both reference BS 7909 as the standard expected.
Can I run a generator inside a building?
Not a fuel-burning one — never. Petrol and diesel generators produce carbon monoxide in significant quantities; CO is colourless, odourless, and lethal at relatively low concentrations, and UK fatalities happen every year from generators run inside garages, tents, partial enclosures, or vehicles. Fuel-burning generators must operate outdoors with adequate ventilation. This is, however, a major advantage of battery power stations: because they have no engine and produce no exhaust or CO, a LiFePO4 battery station can be used safely indoors and on set, which is one of the main reasons they’ve become so popular for interior and sound-critical work. If you need power inside a building, a battery station is the right tool; a fuel generator is not.
What is a Genny Op and do I need one?
A Genny Op (Generator Operator) is a competent person responsible for power-source operation, distribution, fuel or battery management, and electrical safety on a production. UK BECTU practice and insurance expect a Genny Op for any production with meaningful power load — typically anything beyond the smallest documentary or single-camera location — and this holds whether the source is a generator, a battery system, or a hybrid. The Genny Op holds BS 7909 competency, knows the equipment and distribution, manages fuel or battery state, and signs off the installation before energising. Hiring one is cheaper than the consequences of an electrical incident or sustained power failure.