🔥 Fire Safety on Film & TV Sets — UK Production Fire Guide
A UK guide to fire safety on film and TV sets — the elevated fire risk, the Fire Safety Order, ignition and fuel sources, risk assessment, means of escape, detection, and pyrotechnics.
A film or TV set brings together, in one confined space, almost everything a fire needs: powerful heat sources in hot lighting, heavy electrical loads and temporary power, large quantities of combustible material in sets, scenery, drapes, and props, and — on many productions — deliberate fire and pyrotechnics. Add atmospheric smoke and haze, a crowded space full of people who may not know the building, and the pressure of the shoot, and the fire risk is real and serious. Fire safety on set is not an afterthought; it’s a core part of keeping a production safe.
UK fire safety on sets is governed by the same fire safety law as other workplaces — principally the Regulatory Reform (Fire Safety) Order 2005 — which requires a fire risk assessment and appropriate fire precautions, alongside the general health and safety framework and the industry’s production safety guidance. The principles are the familiar ones of fire safety (prevent ignition, control fuel, provide means of escape, detection, and fire-fighting) applied to the specific, elevated risks of the set, with the special effects and pyrotechnics controlled by competent specialists.
This guide covers fire safety on film and TV sets — why the fire risk is elevated, the legal framework, the sources of ignition and fuel on a set, the fire risk assessment, prevention and control, means of escape and keeping them clear, detection and fire-fighting equipment, the special cases of pyrotechnics, naked flame, and atmospheric effects, studio vs location considerations, and the common mistakes. It complements our Fire Safety Equipment and Film & TV Set Safety guides.
Why the Fire Risk Is Elevated on Set
A set concentrates the fire triangle — ignition, fuel, and oxygen — to an unusual degree. Ignition sources abound: hot lighting fixtures (traditional tungsten and HMI lamps run very hot), heavy electrical loads and temporary power (with the fault and overload risks that brings), and deliberate fire effects and pyrotechnics. Fuel is everywhere: sets and scenery are often built from timber, board, fabric, foam, and other combustibles; there are drapes, costumes, props, and set dressing; and atmospheric effects and materials. The space is often confined and crowded with people, many of whom (on location especially) may not know the building or its escape routes. And it all operates under the pace and pressure of production.
This combination makes fire a serious, credible risk on productions — and one that has caused significant fires. For UK productions, managing it is both a legal duty (under the Fire Safety Order and health and safety law) and an essential part of protecting the cast, crew, and the venue. The risk is elevated, so the fire precautions need to match.
The Legal Framework
- Regulatory Reform (Fire Safety) Order 2005: The principal fire safety legislation for England and Wales (with equivalent regimes in Scotland and Northern Ireland). It requires the “responsible person” to carry out a fire risk assessment, put in place and maintain appropriate fire precautions, provide means of escape and detection, and ensure people can escape safely. It applies to the production’s premises and activities.
- Health and Safety at Work Act 1974 and Management Regulations 1999: General duties and risk assessment, including fire.
- Dangerous Substances and Explosive Atmospheres Regulations (DSEAR) and explosives law: Relevant to pyrotechnics and explosive effects — handled by competent, licensed specialists.
- Industry guidance: The production safety guidance covers fire, special effects, pyrotechnics, and naked flame (see our BECTU & Safety Standards guide).
- Venue/studio fire arrangements: Studios and venues have their own fire safety arrangements the production works within.
Sources of Ignition and Fuel on Set
Ignition Sources
- Hot lighting: Tungsten and HMI fixtures run very hot — a major ignition source if too close to combustibles (drapes, scenery, gels igniting).
- Electrical: Heavy loads, temporary power, faults, overloads, and damaged cables — electrical fire risk (see our BS 7909 and Cable Management guides).
- Pyrotechnics and fire effects: Deliberate fire — controlled by SFX specialists.
- Naked flames: Candles, flames, and fire used on camera.
- Hot works: Welding, grinding, and hot work in construction.
- Smoking and other sources.
Fuel Sources
- Sets and scenery: Often timber, board, and combustible construction.
- Drapes, fabrics, and soft furnishings: Highly combustible — flame-retardant treatment important.
- Props, set dressing, and costumes.
- Foam, polystyrene, and modelling materials.
- Flammable liquids and materials: Paints, solvents, fuels, and effects materials.
- Packaging and waste: Accumulated combustible rubbish.
The Fire Risk Assessment
The foundation of fire safety on set is a fire risk assessment — required under the Fire Safety Order — which:
- Identifies fire hazards: The ignition sources and fuel on the set/location.
- Identifies people at risk: Cast, crew, and others, including anyone especially at risk.
- Evaluates and controls the risk: Removing or reducing hazards, and the precautions needed.
- Addresses means of escape: Escape routes, exits, and how everyone gets out safely.
- Addresses detection and warning, and fire-fighting.
- Covers the specific production: Tailored to the set, the location, and the planned activities (including any pyrotechnics, naked flame, or fire effects — which need specific assessment and competent specialists).
- Is reviewed and kept current as the set and activities change.
- Informs the fire plan: Emergency procedures, evacuation, and roles (fire marshals).
Prevention and Control
- Keep ignition away from fuel: Hot lights kept clear of combustibles (drapes, scenery), safe distances, and heat management.
- Electrical safety: Competent temporary power to BS 7909, no overloading, cables protected and maintained (see our BS 7909 and Cable Management guides).
- Flame-retardant treatment: Treating drapes, scenery, and combustible materials with flame retardant where appropriate — a key control given the combustible set environment.
- Control flammable materials: Safe storage and handling of flammable liquids, paints, and solvents; minimising quantities on set.
- Good housekeeping: Removing combustible waste and packaging, keeping the set tidy (also helps escape — see our Cable Management guide).
- Hot work controls: Permits and precautions for welding/grinding in construction.
- Smoking controls: Smoke-free policy and designated areas.
- SFX/pyro control: Deliberate fire and pyrotechnics strictly controlled by competent specialists (below).
Means of Escape
Ensuring everyone can escape safely is a central fire-safety duty — and a particular challenge on a cluttered, dark, crowded set:
- Clear escape routes and exits: Escape routes and fire exits kept clear and unobstructed at all times — NOT blocked by cables, equipment, sets, or kit (a common and dangerous failing on busy sets).
- Adequate exits: Sufficient exits for the number of people, suitably located.
- Exit and escape signage: Clear fire exit and escape route signage (see our Workplace Signage and Emergency Lighting guides), visible even in the dark set environment.
- Emergency lighting: So escape routes are visible if the power fails or in the dark (see our Emergency Lighting guide).
- Set layout and escape: Considering escape when laying out the set — not creating dead ends or blocking exits with scenery.
- Assembly point: A safe assembly point and a way to account for everyone.
- Everyone knows the way out: Cast and crew (especially on location) briefed on escape routes and procedures.
Detection, Warning, and Fire-Fighting
- Detection and warning: Fire detection and a means of raising the alarm appropriate to the premises — and a way to warn everyone (noting that atmospheric smoke/haze can interact with smoke detection, needing management).
- Fire-fighting equipment: Appropriate fire extinguishers (the right types for the risks — including CO2/electrical for electrical fires) and other equipment, accessible and maintained (see our Fire Safety Equipment guide).
- Positioned for the risks: Extinguishers sited where the risks are (near electrical, near pyro/fire effects, in construction).
- Fire marshals: Trained fire marshals/wardens on the production, with clear roles in prevention, evacuation, and using equipment.
- Standby for fire effects: Dedicated fire cover/standby (and sometimes the fire brigade or professional fire safety personnel) for sequences involving fire and pyrotechnics.
- Training: Crew aware of the fire procedures, alarm, and equipment.
- Emergency plan: A clear fire emergency and evacuation plan.
Special Cases: Pyrotechnics, Naked Flame, and Atmospheric Effects
Pyrotechnics and Fire Effects
Deliberate fire, explosions, and pyrotechnics are high-risk and strictly controlled: planned and executed by competent, licensed SFX/pyrotechnics specialists; specific risk assessment and method statement; exclusion zones; dedicated fire cover/standby; safety briefings; and rigorous procedures. This is specialist work — never improvised (see our Film & TV Set Safety guide).
Naked Flame on Camera
Candles, flames, and fire used in shot — controlled with fire precautions, fire cover/standby, clear procedures, and management of the surrounding combustibles.
Atmospheric Smoke and Haze
Smoke and haze machines create atmosphere but can interact with fire detection (triggering or masking) and affect visibility and respiratory comfort — managed by coordinating with the detection system (and venue), ventilation, and ensuring escape visibility isn’t compromised.
Studio vs Location
Studio
Purpose-built studios with fire safety infrastructure (detection, alarms, exits, fire-fighting) and established arrangements the production works within — but still with the elevated set fire risks to manage.
Location
The bigger challenge — unfamiliar buildings whose fire arrangements, escape routes, and detection must be assessed and understood; cast and crew briefed on a building they don’t know; heritage or sensitive buildings needing extra care; and temporary arrangements where needed.
Occupied / Public Buildings
Shooting in occupied or public premises — working within and not compromising the building’s fire safety, protecting other occupants and the public.
Outdoor
Outdoor fire risks (dry conditions, wildfire risk in some settings, fuel and equipment) and the relevant precautions.
Common Mistakes
Blocked Escape Routes and Exits
Escape routes and fire exits blocked by cables, equipment, sets, or kit — a common, dangerous failing on busy sets that can be lethal in a fire. Keep escape routes and exits clear at all times.
Hot Lights Too Close to Combustibles
Hot fixtures placed too near drapes, scenery, or materials — igniting them. Keep hot lights at safe distances from combustibles and manage heat.
No Flame-Retardant Treatment
Untreated combustible drapes, scenery, and materials — fuelling rapid fire spread. Treat combustibles with flame retardant where appropriate.
No Fire Risk Assessment
Working without a proper fire risk assessment for the set/location and activities — a legal failing and a safety gap. Carry out and maintain a fire risk assessment.
Electrical Fire Risk
Overloaded or poorly-managed temporary power and damaged cables — an electrical fire risk. Use competent power to BS 7909 and manage cables (see our BS 7909 and Cable Management guides).
Improvised Pyro / Naked Flame
Fire effects, pyrotechnics, or naked flame without competent specialists, fire cover, and procedures — extremely dangerous. Use licensed SFX specialists with full controls and fire standby.
Atmospheric Smoke Triggering / Masking Detection
Haze and smoke interacting with fire detection without coordination — false alarms or, worse, masked detection. Coordinate atmospheric effects with the detection system and venue.
Poor Housekeeping / Combustible Waste
Accumulated combustible waste and packaging adding fuel and blocking routes. Keep the set tidy and remove combustible waste.
Crew Not Knowing Escape Routes
Cast and crew — especially on location — not briefed on the escape routes and procedures for a building they don’t know. Brief everyone on the fire arrangements.
Wrong or Missing Fire-Fighting Equipment
No extinguishers, or the wrong types for the risks (e.g. water near electrical). Provide appropriate, accessible, maintained fire-fighting equipment (see our Fire Safety Equipment guide).
No Fire Marshals / Emergency Plan
No trained fire marshals or clear evacuation plan. Appoint and train fire marshals and have a clear fire emergency plan.
Conclusion
A film or TV set concentrates the ingredients of fire — hot lighting and heavy electrical loads as ignition, combustible sets, scenery, and drapes as fuel, deliberate fire and pyrotechnics, and atmospheric smoke — in a confined, crowded space, making the fire risk genuinely elevated. Managing it is both a legal duty under the Fire Safety Order and an essential part of protecting cast, crew, and venue, built on a proper fire risk assessment that drives prevention, escape, detection, and fire-fighting tailored to the production.
What keeps a set safe from fire is applying the familiar fire-safety principles to its elevated risks: keep ignition away from fuel (hot lights clear of combustibles), use competent temporary power and managed cabling, flame-retard the combustible set materials, control flammable materials and waste, and — above all — keep escape routes and exits clear at all times, with detection, emergency lighting, signage, appropriate fire-fighting equipment, and trained fire marshals. The deliberate fire of pyrotechnics and naked flame must always be in the hands of competent licensed specialists with fire cover and full procedures, and atmospheric effects coordinated with the detection system. Assess the risk, prevent ignition, keep the way out clear, and have the means to detect and fight fire — and the set’s elevated fire risk is managed into a controlled one that protects everyone on the production. See our Fire Safety Equipment, Emergency Lighting, and Film & TV Set Safety guides for more.
Frequently Asked Questions
Why is the fire risk higher on a film set?
Because a set concentrates the fire triangle — ignition, fuel, and oxygen — to an unusual degree in one confined, crowded space. Ignition sources abound: hot lighting fixtures (traditional tungsten and HMI lamps run very hot), heavy electrical loads and temporary power with their fault and overload risks, and on many productions deliberate fire effects and pyrotechnics. Fuel is everywhere too: sets and scenery are often built from timber, board, fabric, foam, and other combustibles, and there are drapes, costumes, props, and set dressing, plus flammable liquids like paints and solvents. The space is often confined and crowded with people, many of whom — on location especially — may not know the building or its escape routes, and it all operates under the pace and pressure of production. Add atmospheric smoke and haze, which can interfere with fire detection, and you have a genuinely elevated, credible fire risk that has caused significant fires on productions. This is why fire safety on set isn’t an afterthought but a core part of production safety, requiring fire precautions that match the elevated risk — a proper fire risk assessment, prevention, clear escape routes, detection, and fire-fighting.
What law governs fire safety on film and TV sets?
The principal fire safety legislation is the Regulatory Reform (Fire Safety) Order 2005 (for England and Wales, with equivalent regimes in Scotland and Northern Ireland). It requires the “responsible person” to carry out a fire risk assessment, put in place and maintain appropriate fire precautions, provide means of escape and detection, and ensure people can escape safely — and it applies to the production’s premises and activities. Alongside this sit the general health and safety duties under the Health and Safety at Work Act 1974 and the Management of Health and Safety at Work Regulations 1999, which require risk assessment including fire. Where pyrotechnics and explosive effects are involved, the Dangerous Substances and Explosive Atmospheres Regulations (DSEAR) and explosives law are relevant, and these are handled by competent, licensed specialists. The industry’s production safety guidance covers fire, special effects, pyrotechnics, and naked flame, providing industry-specific detail. And studios and venues have their own fire safety arrangements that the production works within. So fire safety on set is governed by the same fire safety law as other workplaces (the Fire Safety Order) plus the general health and safety framework, the specific regulations for pyrotechnics, and the industry guidance — with the production responsible for assessing and managing the fire risk of its set and activities.
Why must escape routes be kept clear on a set?
Because in a fire, blocked escape routes and exits can be lethal — people need to be able to get out quickly and safely, and a set is a particularly challenging environment for escape: it’s often cluttered, dark around the lit area, crowded, and full of people who (on location especially) may not know the building. Keeping escape routes and fire exits clear and unobstructed at all times is a central fire-safety duty under the Fire Safety Order, and it’s a common and dangerous failing on busy sets, where routes and exits get blocked by cables, equipment, sets, props, and kit as the production sprawls. The discipline required is to ensure escape routes and exits are never blocked — not by cable runs, not by equipment or flight cases, not by scenery or set construction — and to consider escape when laying out the set so you don’t create dead ends or block exits with scenery. This is supported by clear fire exit and escape route signage (visible even in the dark set environment), emergency lighting so routes are visible if the power fails, briefing cast and crew on the escape routes (especially on unfamiliar location buildings), and a safe assembly point with a way to account for everyone. A clear, well-signed, well-lit, known escape route is what lets everyone get out safely if fire breaks out — which is why keeping it clear is non-negotiable.
How are pyrotechnics and fire effects handled safely?
Deliberate fire, explosions, and pyrotechnics are high-risk activities that must be strictly controlled by competent, licensed special effects and pyrotechnics specialists — they are never improvised or handled by general crew. The controls include a specific risk assessment and method statement for the sequence, prepared by the competent specialist; exclusion zones keeping people at safe distances; dedicated fire cover and standby (and sometimes the fire brigade or professional fire safety personnel) ready to respond; safety briefings for everyone present before the sequence so they understand the hazards, the signals, and the procedures; and rigorous procedures throughout. Naked flame used on camera — candles, flames, fire in shot — is similarly controlled with fire precautions, fire cover/standby, clear procedures, and careful management of the surrounding combustible materials. The key principle is that anything involving deliberate fire is specialist work requiring competent, licensed people, proper planning and risk assessment, fire standby, exclusion zones, and briefings — reflecting how dangerous fire effects are. This sits within the broader production safety framework where high-risk disciplines are controlled by competent specialists. See our Film & TV Set Safety guide for more on how special effects and other high-risk sequences are managed on a production.
Why does atmospheric smoke and haze need managing for fire safety?
Smoke and haze machines are widely used on sets to create atmosphere and reveal light beams, but the artificial smoke and haze they produce can interact with fire detection systems in problematic ways — it can trigger smoke detectors, causing false fire alarms and disrupting the shoot, or in some circumstances interfere with the detection system’s ability to sense a real fire, which is more serious. It can also affect visibility (including of escape routes) and respiratory comfort. So atmospheric effects need to be managed for fire safety: this means coordinating with the building’s or studio’s fire detection system and the venue — understanding how the detection will respond to the haze and putting appropriate arrangements in place — rather than just running smoke machines without regard to the detection. It also means managing ventilation and ensuring that escape route visibility isn’t compromised by heavy atmosphere. The goal is to use the atmospheric effects the production needs while ensuring the fire detection still works properly to protect everyone, and that people could still find their way out in an emergency. Simply running haze and smoke without coordinating with the detection system — risking either nuisance alarms or, worse, masked detection — is a mistake. Atmospheric effects and fire detection have to be managed together.
What fire-fighting equipment should a set have?
A set should have appropriate fire extinguishers and other fire-fighting equipment suited to the specific risks present, accessible and maintained. Crucially, the right types of extinguisher must be provided for the risks — in particular, CO2 or other extinguishers suitable for electrical fires near the electrical and lighting equipment, since using a water extinguisher on an electrical fire is dangerous. Extinguishers should be sited where the risks are: near electrical and lighting equipment, near any pyrotechnics or fire effects, and in construction and hot-work areas. Beyond extinguishers, the production needs a means of detecting fire and raising the alarm appropriate to the premises, a way to warn everyone, and — for sequences involving deliberate fire and pyrotechnics — dedicated fire cover and standby. Trained fire marshals or wardens should be in place with clear roles in fire prevention, evacuation, and using the equipment, and the crew should be aware of the fire procedures, the alarm, and the equipment. The equipment and arrangements should flow from the fire risk assessment, which identifies the risks and the precautions needed. The combination of the right extinguishers in the right places, detection and warning, fire marshals, fire standby for fire effects, and a clear emergency plan gives the production the means to detect, raise the alarm about, and fight fire — see our Fire Safety Equipment guide for more on extinguisher types and selection.
What’s different about fire safety on location versus in a studio?
The key difference is familiarity and infrastructure. A purpose-built studio has established fire safety infrastructure — detection, alarms, marked exits, fire-fighting equipment — and known fire safety arrangements that the production works within, although the elevated set fire risks (hot lights, electrical loads, combustible sets, effects) still have to be managed. Location shooting is the bigger fire-safety challenge because the production is working in an unfamiliar building whose fire arrangements, escape routes, and detection systems must be assessed and properly understood before and during the shoot, and cast and crew must be briefed on the escape routes and procedures of a building they don’t know — which is much harder than in a familiar studio. Heritage or sensitive buildings need extra care given their construction and value, and temporary fire safety arrangements may be needed where the existing provision isn’t sufficient for the production’s activities. Shooting in occupied or public premises adds the responsibility of working within and not compromising the building’s existing fire safety and protecting other occupants and the public. Outdoor locations bring their own fire risks such as dry conditions and, in some settings, wildfire risk. So while the fire-safety principles are the same everywhere, location work demands much more assessment of and adaptation to an unfamiliar environment, whereas a studio offers a known, equipped baseline to build on. In both cases the production must assess and manage the fire risk of its specific activities and ensure everyone can escape safely.
Who is responsible for fire safety on a production?
Under the Regulatory Reform (Fire Safety) Order 2005, the duty falls on the “responsible person” — in a production context this is the production company/employer and those who have control over the premises and activities, who must ensure a fire risk assessment is carried out and that appropriate fire precautions, means of escape, detection, and arrangements for safe evacuation are in place and maintained. This sits alongside the general health and safety responsibilities, which also rest with the production/employer. Within the production, the responsibility is supported by various roles: a health and safety advisor or fire safety specialist may help with the fire risk assessment and arrangements; trained fire marshals or wardens have clear roles in fire prevention, evacuation, and using fire-fighting equipment; competent licensed special effects and pyrotechnics specialists control any deliberate fire effects; and every crew member has a duty to follow the fire procedures, keep escape routes clear, and act safely. Where the production is working in a studio or a venue, it works within that building’s fire safety arrangements and coordinates with the venue, and where it’s in occupied or public premises it must not compromise the building’s fire safety or endanger other occupants. So the overarching legal responsibility rests with the production as the responsible person and employer, discharged through the fire risk assessment and the fire precautions and roles it puts in place, with everyone on the production contributing to fire safety in practice. See our Film & TV Set Safety guide for how this fits within the production’s overall safety management.